Ionizing Gun and Nozzle
Product Specification
Input Voltage DC24V±5%
Power 4 W
Ion Balance <±15V (Automatic balance, no need to adjust)
Discharge Time Less than 0.5 seconds(At 0.2Mpa air pressure)
Used Pressure 0.01-0.7Mpa clean air,CDA or Nitrogen, recommends to use the max use of 0.5Mpa
Alarm Indication H.V high voltage operation indicator light; ALARM high voltage fault indicator light
Dimension H87xW50xD18mm
Weight 75g
Certification
Decay Time
O
Operating Voltage: DC24V Test Voltage: ±1000V-±100V Temperature: 23±3 C Humidity: 50%±5%
Distance(mm) 150 300
Decay time Positive 0.4S 0.7S
Negative 0.5S 0.9S
Positive
Offset voltage ±10V
Negative
Measurement method:Use a 20PF, 150mm static elimination monitor to measure
0.2Mpa air pressure , the decay time from ±1000V---±100V
The test results is different when testing in different environments, above data is for reference only, please test according to
your using environment.
Specification of Ionizing Air Nozzle
ȹ5mm
(HN-N01)Standard spray head 9mm ȹ3mm
17mm 14mm 11mm 17mm
12mm 9mm ȹ11mm
30mm
ȹ17mm
(HN-N60DW)60°
Shower spray head 9mm ȹ11mm 60° ȹ5mm
ȹ2mm
17mm 12mm 60°
60° 12mm
12mm 5mm 10mm
36mm ȹ12mm
ȹ17mm
(HN-N90DW)90° 9mm 60° ȹ5mm
Shower spray head ȹ11mm ȹ2mm
17mm M12mm 12mm 60°
90°
12mm 5mm 10mm
36mm ȹ12mm
ȹ17mm
11