               HN-04


               Product Description

               Patent technology, using extraction separation design, which is easy to clean the emitter needle and replace high-voltage components.
               Variety of nozzles are optional for more applications place . With power indicator light, high-voltage operation indicator light,
               high-voltage abnormal alarm and cleaning indicator, and it can output remote alarm signals.
               The emitter needle and high voltage module can be quickly replaced, which is convenient for maintenance.
               With a throttle valve connector that can control the air pressure.











               Product Specification
                  Input Voltage      DC24V±5%
                  Power              4 W
                  Ion Balance        <±15V (Automatic balance, no need to adjust)
                  Used Pressure      0.01-0.7Mpa clean air,CDA or Nitrogen, recommends to use the max use of 0.5Mpa
                                     Power indicator light/high-voltage operation indicator light/high-voltage abnormal
                  Alarm Indication
                                     alarm/cleaning indicator
                  Material           Body: ABS stainless steel 304                              Emitter needle: Tungsten
                  Dimension          H92xW53xD21mm
                  Weight             120g

                  Certification




               Decay Time
                                                                               O
                   Operating Voltage: DC24V                  Test Voltage: ±1000V-±100V                  Temperature: 23±3 C                  Humidity: 50%±5%
                            Distance(mm)                       150                       300
                    Decay time         Positive               0.4S                      0.7S
                                       Negative               0.5S                      0.9S
                                       Positive
                   Offset voltage                                           ±15V
                                       Negative
                Measurement method:Use a 20PF, 150mm static elimination monitor to measure
                0.2Mpa air pressure , the decay time from ±1000V---±100V
                The test results is different when testing in different environments, above data is for reference only, please test according to
                your using environment.




               HG-05ECO


               Product Description
               Built-in high-voltage power supply, small size with light weight, low power
               consumption, environmental friendly , no high-voltage wiring, which is more safety
               and convenient to use.
               Automatic ion balance system, ion balance<±15V.
               With normal operation indicator and abnormal indicator, when working abnormal
               the red light indicator will turn on and output 24V relay signal
               Using tungsten alloy emitter needles which is not easy to wear, and can be used in
               cleanroom. Different nozzles can be selected for application in different places.