Page 12 - ESDMAN CO., LTD.
P. 12
Ionizing Gun and Nozzle
Decay Time
Operating Voltage: DC24V Test Voltage: ±1000V-±100V Temperature: 23±3 C Humidity: 50%±5%
O
Distance(mm) 150 300
Decay time Positive 0.4S 0.7S
Negative 0.5S 0.9S
Positive
Offset voltage ±15V
Negative
Measurement method:Use a 20PF, 150mm static elimination monitor to measure
0.2Mpa air pressure , the decay time from ±1000V---±100V
The test results is different when testing in different environments, above data is for reference only, please test according to
your using environment.
HG-03ECO
Product Description
Built-in miniature transformer, lightweight and small body design, with low power
consumption which is environmental protection. No need of external high voltage
wiring safety design, no electromagnetic interference which is more safety and
convinient.
Lightweight gun body is easy to move and operate,when you pulled the trigger,Gas
synchronous output,it can blow the particulate pollutant when eliminiate the static
electricty.
Automatic ion balance system, decay time less than 0.5 seconds, ion balance less than
± 15 V (The distance is 15CM,The pressure 0.5 Mpa )
Using tungsten alloy emitter needle, it can be used for a long time,and which is not
easy to wear, and widely used in cleanrooms.
Product Specification
Input Voltage DC24V±5%
Power About 4W
Decay Time About 0.5 seconds(Distance 15cm,Max air volume)
Ion Balance < ±15V
Ionization Technology High Frequency AC Technology
Dimension(mm) H138xW110xD25mm(Does not contain raised part)
Weight 120g
Air Pressure 0.01-0.7Mpa clean air, CDA recommends to use the max use of 0.5Mpa
Trachea Connector 1/8 standard trachea connector (6mm trachea)
Material Body: ABS emitter needle: tungsten
Certification
Decay Time
O
Operating Voltage: DC24V Test Voltage: ±1000V-±100V Temperature: 23±3 C Humidity: 50%±5%
Distance(mm) 150 300
Positive 0.4S 0.7S
Decay time
Negative 0.5S 0.9S
Positive
Offset voltage ±10V
Negative
Measurement method:Use a 20PF, 150mm static elimination monitor to measure
0.2Mpa air pressure , the decay time from ±1000V---±100V
The test results is different when testing in different environments, above data is for reference only, please test according to
your using environment.
09