Page 12 - ESDMAN CO., LTD.
P. 12

Ionizing Gun and Nozzle



               Decay Time
                   Operating Voltage: DC24V                  Test Voltage: ±1000V-±100V                  Temperature: 23±3 C                  Humidity: 50%±5%
                                                                               O
                            Distance(mm)                       150                       300

                    Decay time         Positive               0.4S                      0.7S
                                       Negative               0.5S                      0.9S
                                       Positive
                   Offset voltage                                           ±15V
                                       Negative
                Measurement method:Use a 20PF, 150mm static elimination monitor to measure
                0.2Mpa air pressure , the decay time from ±1000V---±100V
                The test results is different when testing in different environments, above data is for reference only, please test according to
                your using environment.



               HG-03ECO


               Product Description
               Built-in miniature transformer, lightweight and small body design, with low power
               consumption which is environmental protection. No need of external high voltage
               wiring safety design, no electromagnetic interference which is more safety and
               convinient.
               Lightweight gun body is easy to move and operate,when you pulled the trigger,Gas
               synchronous output,it can blow the particulate pollutant when eliminiate the static
               electricty.
               Automatic ion balance system, decay time less than 0.5 seconds, ion balance less than
               ± 15 V (The distance is 15CM,The pressure 0.5 Mpa )
               Using tungsten alloy emitter needle, it can be used for a long time,and which is not
               easy to wear, and widely used in cleanrooms.


               Product Specification

                Input Voltage        DC24V±5%
                Power                About 4W
                Decay Time           About 0.5 seconds(Distance 15cm,Max air volume)
                Ion Balance          < ±15V
                Ionization Technology  High Frequency AC Technology
                Dimension(mm)        H138xW110xD25mm(Does not contain raised part)
                Weight               120g
                Air Pressure         0.01-0.7Mpa clean air, CDA recommends to use the max use of 0.5Mpa
                Trachea Connector    1/8 standard trachea connector (6mm trachea)
                Material             Body: ABS emitter needle: tungsten
                Certification



               Decay Time

                                                                               O
                   Operating Voltage: DC24V                  Test Voltage: ±1000V-±100V                  Temperature: 23±3 C                  Humidity: 50%±5%
                            Distance(mm)                       150                       300
                                       Positive               0.4S                      0.7S
                    Decay time
                                       Negative               0.5S                      0.9S
                                       Positive
                   Offset voltage                                           ±10V
                                       Negative
                Measurement method:Use a 20PF, 150mm static elimination monitor to measure
                0.2Mpa air pressure , the decay time from ±1000V---±100V
                The test results is different when testing in different environments, above data is for reference only, please test according to
                your using environment.


    09
   7   8   9   10   11   12   13   14   15   16   17