Page 18 - ESDMAN CO., LTD.
P. 18

High Frequency AC Auto-Clean Ionizer



               Features
               Automatic cleaning emitter needle
               Decay time less than 1 seconds(measuring distance 30cm)
               ±10V automatic balance
               Tungsten Alloy emitter needle
               Quick remove front windshield
               RS485 communication is optional
               Alarm and equipment monitoring interface


               Benefits                                               Decay Time
               Can save manual cleaning frequency
               Fast decay time
               Great and stable ion balance                                      1ft.    2ft.    3ft.
               Replace discharge needle
                                                                                 0.8s    1.5s    2.5s
               A utomatic power-off protection when disassembling the front window
               Centralized monitoring                                           30cm    60cm    90cm
               The working status can be monitored at the remote or workbench




               Product Specification

                   Model Number                     H1201SAC                        H1211SAC
                   Panel Position                   Front side                       Top side
                   Input Voltage                                    About 12W
                   Discharge Time             About 0.8S(measuring distance 30cm, the max air volume, no filter cotton )
                   Ion Balance                                        <±10V
                   Ionization Technology                   High-frequency ionization technology
                   Discharge Needle Material                       Tungsten Alloy
                   Emitter Needle                           Emitter needle could be replaced
                                        High voltage operation/abnormal indication light; Fan operation/abnormal indication light;
                   Alarm Indication
                                                        Air volume indication,clean alarm indication
                   Signal Output              Red light turn on when high voltage or fan abnormal,output DC 24V signal
                   Network Monitoring
                   Air Volume                                      2.2-4.1m³/min
                   Filter                               Online version is optional, online monitoring
                   Ozone                                    Under 0.04ppm (distance 150mm)
                   Operation Environment              Temp:0-40°C, Hum:20-75%(no water condensation)
                   Dimension                               H190xW143xD90mm(without bracket)
                   Weight                                          Approx1.4Kg
                   Shell Material            Double sided galvanized steel sheet electrostatic sprayed /Stainless steel 304
                   Warranty                                          One year
                   Certification





               H1212SAC / H1213SAC

               Product Description
               Using the high-frequency AC ionization technology,
               H1212SAC/H1213SAC can be used on the workbench, it has
               built-in automatic cleaning brush,which can reduce manual
               cleaning frequency, and provide a great electrostatic
               protection in large area, optional auxiliary lighting,
               adjustable air volume, with fan working abnorma and static
               elimination abnormal alarm. It can output alarm signals,
               remote monitoring, and with optional network monitoring.


    15