High Frequency AC Auto-Clean Ionizer
Features
Automatic cleaning emitter needle
Automatic locking function to avoid accidental touch
Decay time less than 1 seconds(measuring distance 30cm)
Automatic balance function
LED alarm display / equipment monitoring interface / network monitoring
Quick remove front windshield with automatic power off protection
Electrostatic spraying of shell / stainless steel shell can be customized
Benefits
Can reduce manual cleaning frequency
Avoid non-engineers adjusting operating parameters without permission
Fast decay time, can meet the static elimination request of moving stuff
The effect of static elimination will be poor after long-term use, and the effect can be restored by replacing the emitter needle
When the voltage is high/fan is abnormal, the LED light will turn red and the buzzer will run
It can be maintained quickly, and the automatic power off function can protect the personnel who do the maintenance won’t be injured
by accident
Two types of wind windows is optiona, direct wind and diffuse wind
Decay Time
O
Operating Voltage: DC24V Test Voltage: ±1000V-±100V Temperature: 23±3 C Humidity: 50%±5%
Distance(mm) 300 600 900
Decay time Positive 0.9S 2.2S 4.2S
Negative 1.0S 2.7S 4.8S
Positive
Offset voltage ±10V
Negative
Measurement method:Use a 20PF, 150mm static elimination monitor to measure
When the air volume is maximum, the decay time from ±1000V---±100V (this test result is based on using the straight wind window)
The test results is different when testing in different environments, above data is for reference only, please tkest according to
your using environment.
Product Specification
Model Number H1212SAC H1213SAC
Input Voltage DC24V±5%
Discharge Time Less than 1 S (measuring distance 30cm, the max air volume, no filter cotton )
Ion Balance <±10V
Ionization Technology High-frequency ionization technology
Discharge Needle Material Tungsten Alloy
Emitter Needle Emitter needle could be replaced
High voltage operation/abnormal indication light; Fan operation/abnormal indication light;
Alarm Indication Air volume indication,clean alarm indication
Signal Output Red light turn on when high voltage or fan abnormal,output DC 24V signal
Network Monitoring
Air Volume 2.2-4.1m³/min ×2 2.2-4.1m³/min ×3
Filter 30ppi filter cotton is optional (120*120mm)
Ozone Under 0.04ppm (distance 150mm)
Operation Environment Temp:0-40°C, Hum:20-75%(no water condensation)
Dimension L620×W150×H90mm(without bracket) L1020×W150×H90mm(without bracket)
Weight About 4.5Kg About 5.5Kg
Shell Material sided galvanized steel sheet electrostatic sprayed /Stainless steel 304