Page 23 - ESDMAN CO., LTD.
P. 23

Electrostatic Voltmeter



               Electrostatic on-line monitor(sensor) parameters
                         Rated voltage                      DC:12V
                         Device power consumption           0.6W
                         Working temperature                -40°C~85°C
                         Working humidity                   0~100%RH
                         Signal output                      RS485
                         Communication distance             <500m
                         Data update period                 3-5 times/sec
                         LED                                Level 1: Yellow Level 2: Orange Level 3: Red
                         Normal                             Green
                         Alarm indication                   Buzzer
                         Startup stand-by time              5S
                         Electrostatic field measurement range  0~+/-2000V
                         Resolution                         1V
                         Accuracy (25mm) measurement        0-30V, <1V ;  31V-2000V, <5%
               Notes
               This product can be designed into a bar shape according to the production line, and real-time online monitoring and alarm of All-round
               static voltage static voltage can be carried out for large-area production, which can ensure that the product won’t be interfered by static
               electricity.
               Generally, for the measured object, the larger area and the closer distance between the probe and the measured object, the testing
               accurancy would be higher. After the probe is installed, The deviations of the shape of the tested object and the test distance can be
               compensated by calibration.
               The probe is grounded. The metal casing is grounding through the bracket.

               Networking Method
               Probe to data collector: RS485.
               Data collector to computer: TCP/IP network cable.
               When multiple probes are networked, the data collector is connected to a serial server (PoE, RS485) through a network cable, and the
               serial server is also connected to a computer through a network cable.
                                                Pic 4 Upper computer software
                 The output protocol format of the digital signal output port is ASCII code, and the data is separated by spaces. The
                 specific content is shown in form 1.
                             Temperature   Humidity    Voltage
                 Frame header                                    Sensor value  Sensitivity  Frame end
                                 (°C)        (%)        (kV)
                      BG         %6.2f      %7.2f       %7.2f       %7.2f       %7.2f       /r/n

                                           Table 1 Limited Digital Signal Output Protocol
               The sensor can work independently, communicate directly with the computer through the serial port protocol, and also can detect by
               multiple sensors in network. The figure shows two typical network detection methods.

               Application


                         Electrostatic sensor

                         Electrostatic sensor
                                             Serial Server  Router    Router    Computer

                         Electrostatic sensor
                                               Typical networking detection application 1


                                     Electrostatic sensor   GPRS DTU

                                     Electrostatic sensor   GPRS DTU               Computer


                                     Electrostatic sensor   GPRS DTU
                                               Typical networking detection application 2


                                                                                                                   20