Page 26 - ESDMAN CO., LTD.
P. 26
Wrist Strap On-line Monitor
001-0560
Power input 9 VDC alkaline battery
±0.00 to 1.49kV (low range) ±1.0 to ±20kV (high range),
Testing range
automatic jump
Flat panel inspection ±0.00 to 300V
LED display 3.5 digits, bar graph, positive-red, negative-blue
Response <1 second, display update every 5 times
Accuracy ±10%
Automatic power off Automatic power off function-setting 5 minutes
Operating environment 10°C-40°C, 0-60%RH (no condensation)
Encapsulation Conductive Resin(ABS)
Dimension 123x73x25mm
001-5181; 001-5182
Product Features
Real time monitor single wrist strap grounding function.
Monitor has OFF function,dial switch to ON,red light illuminate and monitor will
turn green while connect wrist strap.
Plug wrist strap into monitor socket,monitor will alarm when wear wrist strap
abnormal.
Monitor will alarm when wrist strap is in open circuit or poor contact.
Monitor will alarm when grounding cord is in open circuit accidentally.
Continuously monitors the single wire wrist strap and the grounding of device .
Wrist strap alarm limit: 1.2 M (factory preset, and the resistance value limit also can
be adjusted on the meter according to customer's production environment.)
Accuracy: <+10%
When monitor alarm,red LED light flashes and comes with buzzer sounds.
Suitable for any kind of single wrist strap.
Beautiful appearance, strong anti-interference ability.
Calibration Method
Install wrist strap monitor to the working area, and plug power adapter into wrist strap on-line monitor 001-5181/001-5182.
Plug the “OP" banana jack from Calibration meter 001-1005 into “wrist strap” hole on 001-5181/ 001-5182.
Cut off the GND connection of wrist strap on-line monitor, and connect it to the GND wire of calibrator.
Turn the switch of 001-5181/ 001-5182 to ON, green light illuminate, press the green button on the calibrator, red light illuminate with
buzzer sounds, indicating that the meter is normal and the calibration is done.
001-5181 001-5182
Monitor number of single wrist strap 1 2
Indicate that the personnel grounding connect is normal, and the wrist strap
LED status(Green light illuminate) grounding connection is well.
Indicate that the personnel grounding connect is abnormal, please check the
LED status(Red light with buzzer sounds )
wrist strap wearing and grounding connection.
Wrist strap alarm limit Wrist strap alarm limit: 1.2 M (factory preset, also can be adjusted on the meter
according to customer's request.)
Power supply AC100~240V50/60Hz; DC6V
Meter size 60x58x27(mm) 101x58x27(mm)
Weight 60g(without power supply) 110g(without power supply)
Anti-interference ability Normal
Accuracy <±10%
Application 0°C-60°C, Indoor use
23