Wrist Strap On-line Monitor
Product Specification
001-8103 001-8103A
Monitor number of dual wrist strap 2 2
LED status(Wrist strap monitor light) LED light illuminate gray indicates the dual wrist strap are not inserted into monitor
Indicate that the personnel grounding connect is normal, and the wrist strap grounding
LED status(Green light illuminate) connection is well
Indicate that the personnel grounding connect is abnormal, please check the wrist
LED status(Red light with buzzer sounds ) strap and grounding connection
The frequency of the alarm sound is different for different stations, which is convenient
Alarm
for personnel to distinguish
Wrist strap alarm limit 1.5M<R<10M/35M(factory preset) 60g(without power supply)
Open circuit voltage of dual wrist strap - 200mV
Sealing voltage of dual wrist strap - 40mV/1M
ESD table mat 1 1
The LED light is off when the table mat is The LED light illuminate Green when the
ESD table mat LED status
grounding normally table mat is grounding normally
Indicates that ESD table mat GND connection is abnormal, and there is an audible
ESD table mat LED status (Red light
illuminate) alarm. Please check the grounding of ESD table mat and the quality of ESD table mat is
abnormal or not
The green light is on when testing value
ESD table mat resistance range setting below 3.5M, the red light is on at 3.7M to Two-switch design of 6.5M and 10M are
give an alarm optional
Open circuit voltage of ESD table mat - 64mV
Sealing voltage of ESD table mat - 135mV/10M
Accuracy 10M+/-10%,35M+/-20%
Power supply AC100~240V50/60Hz; DC18V; 200mA or above AC100~240V50/60Hz; DC12V; 200mA or above
Meter size 103x128x36mm(LxWxH),With two wrist strap operator remotes
Meter material Double sided galvanized steel sheet electrostatic sprayed and Stainless steel 304 are optional
Application 0°C-60°C, Indoor use
001-9502; 001-9503
Product Features
Measure single wrist strap system resistance in real time, which ensure the
personnel grouding connection is more safety and stable.
Start testing while plug wrist strap into monitor, no monitoring turn off function.
Monitor two dual wrist straps of two station and one ESD table mat or grounding
connection, it’s convenient to support different options for customer’s request of
different stations.
The wrist strap alarm has max limit and min limit alarm indication, which can
determine short circuit and open circuit of wrist strap by testing to ensure the
reliability and safety of grounding connection.
The ESD table mat alarm value is set by monitoring the resistance range of the
ESD table mat to ensure the efficiency and stability of the electrostatic
discharge path between the ESD table mat and the ground wire. The resistance
setting of the ground connection have multiple gears, which is convenient for
customers to choose the impedance of different meter to the ground, to ensure
the unobstructed release path of the equipment to the ground, and to ensure the
safety of the product.
Accuracy:10M+/-10%, 35M+/-20%
Aluminum alloy casing design: Stylish appearance and with good shielding
performance.