Grounding System



               Product Specification
                                                   001-8101             001-8101            001-8102
              Monitor number of dual wrist strap      1                   2                   4
              LED status(Wrist strap monitor)   LED light illuminate gray indicates the dual wire wrists trap are not plugged into the monitor
                                                Indicating that the personnel grounding connect is normal, and the wrist strap
              LED status(Green light illuminate)
                                                                grounding connection is well
                                             Indicating that the personnel grounding connect is abnormal, please check the wrist
              LED status(Red light with alarm)
                                                               strap and grounding connection
                                             The frequency of the alarm sound is different for different stations, which is convenient
              Alarm
                                                                 for personnel to distinguish
              Wrist Strap resistance range setting                 1.1M/1.5M<R<10M/35M
              Open circuit voltage of dual wrist strap                  200mV
              Sealing voltage of dual wrist strap                      40mV/1M
              ESD Table Mat                           1                   2                   2
              ESD Table Mat LED status              The LED light is green when the table mat is grounding normally
                                              Indicating that ESD table mat GND connection is abnormal, and there is an audible
              ESD Table Mat LED status (Red light illuminate) alarm. Please check the grounding of ESD table mat and the quality of ESD table mat is
                                                                     abnormal or not
              ESD Table Mat resistance range setting      Two-switch design of 3.5M and 6.5M are optional
              Open circuit voltage of ESD Table Mat                     164mV
              Sealing voltage of ESD Table Mat                         135mV/10M
              Grounding wire number                   1                   2                   2
              Grounding connection resistance range setting              10
                                             The green light illuminate, indicating that the resistance of the monitoring is less than
              Grounding connection LED status
                                                                     the setting value
              Grounding connection LED status(Red   Indicating that the equipment is grounded abnormally.Please check whether the,
              light illuminate)                         monitor and ground wire are commecting well or nott
              Open circuit voltage of grounding connection              164mV
              Sealing voltage of grounding connection                  65mV/3
              Accuracy                                            10M+/-10% ;  35M+/-20%
              Power Supply                                 AC100~240V50/60Hz; DC12V; 200mA or above
              Meter Size                       131mmx55mmx27mm     156mmx66mmx28mm     156mmx66xmmx28mm
              Meter Material                                       Aluminum alloy casing
              Application                                           0°C-60°C, Indoor use




               001-9901; 001-9902; 001-9204



               Product Features
               Equipment Ground Monitor can continuously monitor the grounding status of equipment, ESD grounding system and resistance of
               equipment casing.
               Real-time monitoring of the on-off condition of the grounding wire.
               24 hours real-time monitor
               Audible alarm will enable when the resistance is over the limited resistance, to ensure the safety of production.
               Specific limits of resistance can be set according to customer requirements to accurately control the grounding system.
               The monitoring resistance range can be set in the range of 0-25 ,accuracy: +/-1%.
               Wireless transmission or RS485 communication mode, suitable for different working conditions.
               With alarm indicator, which can add external red and green LED alarm indicator.
               Built-in LCD display which can display the resistance of setting value, testing value and monitoring status.













    29
   27   28   29   30   31   32   33   34   35   36   37