Page 5 - ESDMAN CO., LTD.
P. 5
DC Auto-Clean Ionizer
Model Number DC1201C DC1201SAC
Weight Approx 2.2Kg
Shell Material Double side galvanized steel sheet / electrostatic sprayed
Warranty One year
Certification
DC1212SAC / DC1213SAC / DC1212C / DC1213C
Product Description
The constant DC static elimination fan generates positive/negative ions through corona of emitter needle to neutralize static electricity.
DC1212SAC and DC1213SAC have built-in cleaning brushes, which can automatically clean the emitter needles when the machine is
turned on. cleaning period can be set within 1-999 hours.
Preset automatic cleaning period , or manually clean the emitter needle with one button.
(DC1212C/DC1213C without cleaning brush), the output amount of positive/negative ions can be manually adjusted to achieve the best
neutralization effect.
The unique post-emitter design makes the ion distribution more uniform, it is suitable for the control of ESD processes in the cleanroom
environment.
RS485 networking mode is optional, computer terminal software monitoring.
Features Benefits
Balance voltage adjustment gear Adjust voltage to adapt to specific working conditions
Automatic cleaning emitter needle Can save manual cleaning frequency(DC1212C/DC1213C has no automatic
Automatic locking function to avoid accidental cleaning function)
touch Avoidn on-engineer adjusting operating parameters without permission
Quick remove back windshield Easy to maintain and clean the emitter needle
Emitter needle could be replaced The effect of static elimination will be poor after long-term use, and the
LED alarm display / equipment monitoring effect can be restored by replacing the emitter needle
interface / network monitoring When the voltage is high/fan is abnormal, the alarm will light up and the
Electrostatic spraying of shell / stainless steel buzzer will run
shell can be customized Optional casing can adapt to different working conditions
Decay Time
Operating Voltage: DC24V Test Voltage: ±1000V-±100V Temperature: 23±3 C Humidity: 50%±5%
O
Distance(mm) 300 600 900
Decay time Positive 0.9S 2.2S 4.2S
Negative 1.0S 2.7S 4.8S
Positive
Offset voltage ±10V
Negative
Measurement method:Use a 20PF, 150mm static elimination monitor to measure
When the air volume is maximum, the decay time from ±1000V---±100V (this test result is based on using the straight wind window)
The test results is different when testing in different environments, above data is for reference only, please test according to
your using environment.
02