Page 39 - ESDMAN CO., LTD.
P. 39

Dual Wrist Strap/Footwear Tester



               Installation













                                                        Blue wire  Black wire

                            Chart A              Chart B      Chart C                Chart D














                                Chart E                       Chart F                    Chart G






               001-6505;  001-6506 (LED display version)















                          001-6505                       001-6506                       001-6506
                                                                                    LED display version


               Specification
               Part Number                            001-6505           001-6506     001-6506(LED display version)
               LCD Display                               ×                  ×                  ‹
               LED Display                              ‹                   ‹                  ‹
               Test Buttom                           Press button       Press button       Touch button
               Test Wrist Strap Only                    ‹                   ×                  ‹
               Test Footwear Only                       ‹                   ×                  ‹
               Test both wrist strap and footwear       ‹                   ‹                  ‹
               Independent testing of footwear          ‹                   ‹                  ‹
               Max and min limits of ESD wrist strap test   750K-10M     750K-10M         750K-10M/35M
               Max and min limits of ESD footwear    750K-100M          750K-100M          750K-100M/1G
               Power Supply                          9V battery          9V battery       Power Adapter
               External Power Supply (power adapter)         AC110-240V,DC12V,50/60HZ,500mA or above
               Dimension                                           200 x 136 x 42mm (LxWxH)
               Installation Method                             Wall mounted version or stand version
               Operation Environment                                 0°C~60°C, Indoor use


                                                                                                                   36
   34   35   36   37   38   39   40   41   42   43   44